Required information, setup and verification for Net Eco portal connection.
Read installation data from a supported NetEco portal, using its base URL and authorised account.
Confirm portal access, select only the agreed installations and complete any approval or multi-factor step before validating the data.
Connection type: Portal connection.
Provide the correct portal URL and keep certificate validation enabled. If the certificate is invalid, ask the portal operator to fix it before commissioning.
Provide your company and contact person, the intended Insights account, the source identifiers and explicit permission for the requested scope. Include a recent source example for verification.
| Information / setting | What is needed | Supplied or configured by |
|---|---|---|
| Source endpoint (BASE_URL) | Exact endpoint for this customer or deployment; confirm it is reachable by the collection service. | Customer / installer |
| Account username (USERNAME) | Account name with access to the requested data. | Customer / installer |
| Account password (PASSWORD) | Share the source-account password through the secure channel agreed with Eniris. | Customer / installer |
| Time zone (TIMEZONE) | Time zone of the source timestamps, for example Europe/Brussels; identify any files already using UTC. | Customer / installer |
| Installation scope (INSTALLATION_ID_ALLOW_LIST) | Exact installation IDs or numbers to include. Agree explicitly before including every installation. | Customer / installer |
| Exclusions (INSTALLATION_ID_DENY_LIST) | IDs that must not be processed; Eniris checks the identifier type used by this connector. | Customer / installer |
| Certificate validation (SSL) | Keep source certificate verification enabled. Resolve invalid certificates with the source operator. | Eniris with source owner |
Check that the first collection completed, then open the intended Insights account and verify the relevant measurements or metadata. Compare source IDs, timestamps and units with the original source. Check the next scheduled execution as well. An active schedule or a healthy job alone does not prove that every requested measurement was received.
For ordinary onboarding meters, creation requests an immediate first run and keeps recurring collection active. Source publication times, upload intervals and provider limits still apply; immediate collection cannot manufacture missing source data.
Provide Eniris with the connection name, account/site scope, time of the attempt and the exact error. Check source availability and access permissions before retrying. Share a source screenshot or sample without passwords or tokens.
Onboarding classifies this portal connection as free. This label does not establish the terms of a separate provider subscription or equipment licence.