Configure the SmartLogger FTP report and verify CSV measurements in SmartgridX.
Before changing the logger, request dedicated FTP credentials from Eniris. Provide the site name, logger model, firmware and serial number, time zone, devices to include and installer contact. Eniris supplies the destination address, protocol, port, username, password and remote folder. Use the issued settings exactly; do not substitute your manufacturer portal login.
Follow the preparation and acceptance checklist. Confirm the export format with Eniris using an original sample file before commissioning. A working FTP connection alone does not prove that measurements can be imported.
The menu and report test are described in Huawei's SmartLogger3000 manual, section 8.2. The ingestion profile below follows the Eniris Huawei configuration guide.
| Export setting | Eniris Format 4 ingestion profile |
|---|---|
| File format | Format 4 |
| File name | minYYMMDD.csv |
| Time format | YY-MM-DD |
| Export mode | Cyclic |
| Export interval | 5 minutes or longer, as agreed with Eniris |
| File mode | Accumulated |
| Remote directory | Use the issued folder; the existing Eniris profile uses /files |
Do not assume every SmartLogger firmware exposes identical formats or security options. If a setting is absent, send the model, firmware and available export options to Eniris before changing the profile.
Record the upload time and result. Ask Eniris to confirm a new file in the assigned folder and measurements in the correct Insights account. Compare device IDs, timestamps, units and values with the logger. Check another scheduled upload to confirm that recurring delivery works. The initial SmartgridX retrieval can only process files that have already arrived.
If no file arrives, check the issued destination, credentials, folder and network access. If a file arrives without measurements, send Eniris the filename, logger model, export settings and affected time range. Keep passwords out of screenshots.