| Apparaattype | Varianten | RS485 | Reactief vermogensbeheer |
|---|---|---|---|
| PV Ongrid Inverter, 1-Phase | HPK 1000/1500/2000/2500/3000, HPS 3000D/3680D/4000D/5000D/6000D, HPS 3000P/3680P/4000P/5000P/6000P | ✅ | — |
| PV Ongrid Inverter, 3-Phase | HPT 3000P/4000P/5000P/6000P/8000P/10000P/12000P/15000P, HPT 15KP/20KP/25KP/30KP, HPT 15K/17K/20K/22K/25K, HPT 30K/33K/36K/40K/50K, HPT 60K/70K/80K | ||
| Hybrid Inverter | HES 3000/3680/4000/5000/6000, HHS 3000/3680/4000/5000/6000, HHT 5000/6000/8000/10000/12000/15000 |
Deze integratie is niet getest met alle hierboven genoemde apparaten, maar aangezien ze allemaal hetzelfde communicatieprotocol gebruiken, zouden ze zonder problemen moeten werken.
De SmartgridOne Controller en de Hypontech omvormers communiceren via RS485.
| Apparaat | SmartgridOne Controller model OM1 | SmartgridOne Controller model IG8 | RS485-USB-converter | RS485-Ethernet-converter |
|---|---|---|---|---|
| RS485A (Pin 3) | RS485 A | RS485_POS | RS485 A | TX+ |
| RS485B (Pin 4) | RS485 B | RS485_NEG | RS485 B | TX- |
| N/A | RS GND | GND | Niet beschikbaar | G |