In beta and available on request. The additions in this overview require the matching integration or controller update and are not confirmed as part of the standard customer release. Request them through your existing Eniris support conversation. The status applies to these additions, not to every existing function of the devices listed elsewhere on this page.
| Model / system | Beta addition | Validation and conditions |
|---|---|---|
| Autel Modbus chargers | Report rejected setpoint writes as failed commands | Requires the matching controller update |
See integration details for connection requirements and operating limitations.
| Device Type | Variants | Modbus TCP (Ethernet) | RS485 |
|---|---|---|---|
| MaxiCharger DC Compact | 40 kW | ✅ | ✅ |
| MaxiCharger DC Fast | 40–240 kW | ||
| MaxiCharger AC Ultra | 2 × 22 kW | ❌ |
For correct Ethernet wiring, follow the guidelines for Ethernet wiring.
| Device | SmartgridOne Controller model OM1 | SmartgridOne Controller model IG8 | RS485-USB converter | RS485-Ethernet converter |
|---|---|---|---|---|
| RS485 A | RS485_POS | RS485 A | TX+ | |
| RS485 B | RS485_NEG | RS485 B | TX- | |
| RS GND | GND | Not available | G |
After the electrical installation of a charger is complete, follow these steps to configure communication with the SmartgridOne Controller.
192.168.1.100)5029600None81| Setting | Description | Example |
|---|---|---|
| OCPP IP | IP address of the SmartgridOne Controller | 192.168.1.100 |
| OCPP PORT | Modbus port number | 502 |
| MGR IP/URL/PORT | Optional backend connection details | – |
| Running Environment | Corresponding operating region | Europe |
A failed Modbus setpoint write is reported as a failed command instead of a successful application. This improves fault visibility; it cannot itself make an unreachable charger accept a command.