| Device Type | Modbus TCP (Ethernet) | RS485 | Curtailment | Reactive power control |
|---|---|---|---|---|
| Solis 3t10K HVES G5 | experimental | ✅ | ✅ | — |
| Solis S5-EH1P(3-6)K-L | ✅ (only with Solis data logger) | |||
| Solis S5-EH1P(8-10)K-L-PLUS | ||||
| Solis S5-EA1P3K-L | ||||
| Solis S6-EH3P(8-15)K02-NV-YD-L | ||||
| Solis S6-EH3P(5-10)K-H-EU | ||||
| Solis S6-EH3P(5-10)K2-H | ||||
| Solis S6-EH3P(12-20)K-H | ||||
| Solis S6-EA1P(3.6-6)K-L | ||||
| Solis S6-EO1P(4-5)K-48-EU | ||||
| Solis S6-EH3P(30-50)K-H | ||||
Currently, only the connection via RS485 has been tested, but you may also be able to run the inverter via Ethernet.
| Feature | Applies to | Status |
|---|---|---|
| Battery setpoint and AC setpoint control (automatic switchover) | Solis hybrid inverters with remote dispatch support | Standard |
| AC setpoint control only (driver option) | Solis hybrid inverters with remote dispatch support, for example parallel master/slave systems | Standard |
| Battery standby at a 0 W battery setpoint in AC setpoint control only mode | Solis hybrid inverters with remote dispatch support, with AC setpoint control only selected | In beta and available on request (software tested, field validation open) |
Battery standby in AC setpoint control only mode: in beta and available on request. With AC setpoint control only selected, a 0 W battery setpoint in the standard version keeps the inverter regulating its AC port. The inverter can then still charge or discharge the battery on its own logic, for example from surplus production it measures with its own meter. With this beta change, the Controller puts the battery in standby once the battery setpoint has been 0 W for three minutes and no PV curtailment is needed, in the same way as in the automatic mode. The battery leaves standby as soon as the planning asks for charging or discharging again. This change is not yet part of the standard version and can be requested via Eniris support. Validation on an installation is still open.
Solis Inverter Firmware Ensure that you have the latest firmware installed on your Solis inverter. The functionality of external control features like battery control and curtailment is dependent on the firmware version.
The setup of your Solis is an important factor in which EMS-features supported:
Curtailment is now supported for Solis hybrid inverters. The latest firmware version by Solis includes curtailment registers that allow external control of the inverter's output power without writing to the flash memory.
The wiring between the SmartgridOne Controller and the Solis can be done with the following guides:
| Model | Page |
|---|---|
| 3t10K HVES G5 | Wiring configuration for 3t10K HVES G5 |
| S5-EH1P(3-6)K-L | Wiring configuration for S5/S6 Series |
| S5-EH1P(8-10)K-L-PLUS | |
| S5-EA1P3K-L | |
| S6-EH3P(8-15)K02-NV-YD-L | |
| S6-EH3P(5-10)K-H-EU | |
| S6-EH3P(5-10)K2-H | |
| S6-EH3P(12-20)K-H | |
| S6-EA1P(3.6-6)K-L | |
| S6-EO1P(4-5)K-48-EU | |
| S6-EH3P(30-50)K-H |
If your model is not listed, we refer to the manual of the Solis inverter. It should always include a section on how to wire a rs485 communication with external EMS-systems.